Printed 2026-10-21 from blueflo.tech/b/920-prospect-place-brooklyn, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).
built 1906 · 4 stories · 8 apartments · BIN 3031291 · BBL 3012350023
- 2 open immediately hazardous (class C) HPD violations about doors and windows and heat or hot water
- City records list the water service line's material as unknown (lead not ruled out)
- 8 open HPD violations about building conditions
- In the Crown Heights North II Historic District: exterior changes need Landmarks Commission approval
- Outside FEMA's 1% annual-chance flood zone; no mapped stormwater flooding
- No heat or hot water complaints filed last winter
920 PROSPECT REALTY LLC
How often each problem is reported
2024 – 2026- Safety3 reports2024Safety · May 2024 · 1 report (1 complaint)May 16, 2024Safety · Dec 2024 · 1 report (2 complaints)Dec 12, 2024Dec 12, 2024 (2nd)2025Safety · Oct 2025 · 1 report (2 complaints)Oct 20, 2025Oct 20, 2025 (2nd)2026
- Doors or windows2 reports2024Doors or windows · Dec 2024 · 1 report (1 complaint)Dec 12, 20242025Doors or windows · Oct 2025 · 1 report (1 complaint)Oct 20, 20252026
- Plumbing2 reports2024Plumbing · Nov 2024 · 1 report (1 complaint)Nov 17, 2024Plumbing · Dec 2024 · 1 report (1 complaint)Dec 12, 202420252026
A filled month had a report to HPD; darker means more than one, and the past year is brightest. Tap one to read it. Complaints within a week count as one report. Records list complaints filed, not conditions found.
Apartments named in these records
Heat and hot water
Issues on record (2024) · 1 complaint, 2024Boiler burning No. 2 oil (Peerless, Jot-Tw-300S PEERLESS, JOT-TW-300S), registration expired since Aug 1997
Latest boiler work permit 1997
What this counts
DOB boiler permits (BIS and DOB NOW); a permit dates work, not the boiler's age
- Boiler inspection filingsno recordNo boiler filings under this building's ID
- Heat and hot water complaintsfound0 heat or hot water complaints
Water and pipes
Issues on record · 2 complaints, 2024Unknown - Lead Status Unknown (records)
Pests and cleanliness
2 complaints, 2024–2025Fire and safety
Issues on record, most recently 2023Electrical
1 complaint, 2025Structure and facade
Issues on record, most recently 2025In the Crown Heights North II Historic District
- Facade ratingnot requiredNot required: facade inspections apply only to buildings taller than 6 stories
- Sidewalk shed and scaffoldingno recordNo sidewalk shed permits on record
Flooding
No issues on recordOutside FEMA's 1% annual-chance flood zone: X
What this counts
Effective FIRM zones touching the building footprint
Extreme storm, 2080 sea levels: Not in mapped flooding; Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)
What this counts
Mapped ponding touching the building footprint
Above grade
Rent and tenancy
On the state listOn the state's list of buildings with at least one rent-stabilized apartment (2024 registrations); listed for this tax lot (1 addresses), not under this building's address. Listed under the J-51 tax program, so stabilization can end when the exemption does
What this counts
The list doesn't say which apartments are stabilized, and being listed isn't proof of current status. For a specific apartment, request its rent history from HCR
General condition and all records
8 open: 8 about building conditions — walls, floors and stairs (4), fire safety (2), doors and windows (1), heat or hot water (1); 2 immediately hazardous (class C). Also 1 older record from 1992 never closed. 4 further violations from 2024 were closed. 198 violations on record in all, 1990–2025 — the 13 most recent are listed here
What this counts
Open HPD violations inspected in the last 10 years; class C = immediately hazardous. Paperwork = failure to file, notify or certify
1 open: 1 about filings or paperwork
What this counts
Open DOB, ECB and DOB NOW Safety violations, any date, one per violation. ECB class 1 = hazardous, class 2 = major
4 safety, 2 doors or windows, 2 plumbing, 1 appliances, 1 electrical, 1 general repairs, 1 heat or hot water, 1 paint or plaster, 1 pests, 1 unsanitary conditions
What this counts
HPD complaints received in the last 2 years; the list below is every complaint on record for the last three years
5 permits since 1990
What this counts
DOB permits issued (DOB NOW and legacy BIS), one per job and work type; excludes sheds
Nothing on record
- Gas pipingno recordNo open gas piping filing violations. Inspection results themselves are not published
- Energynot requiredNot required: energy reporting applies to buildings over 25,000 sq ft
- Elevatorsnot requiredNo elevators registered to this building
Sources
23 datasetsFEMA
- FEMA National Flood Hazard Layer2026-10-20
- OpenFEMA NFIP Redacted Claims (v3)2026-09-09
NYC DCP
- NYC GeoSearch (address directory)2026-10-20
- PLUTO (tax lot data)2026-08-24
NYC DEP
NYC DEP / Mayor's Office
- NYC Stormwater Flood Maps2024-07-03
NYC DOB
- DOB NOW Elevator Safety Compliance2026-10-19
- DOB NOW: Build – Approved Permits2026-10-19
- DOB NOW: Safety Boiler2026-10-19
- DOB NOW: Safety – Facades Compliance Filings2026-10-19
- DOB Permit Issuance (BIS)2026-10-19
- DOB Safety Violations2026-10-19
- DOB Violations2026-10-19
NYC DOB / Mayor's Office
NYC HPD
- Buildings Subject to HPD Jurisdiction2026-08-12
- Housing Maintenance Code Complaints and Problems2026-10-20
- Housing Maintenance Code Violations2026-10-19
- Multiple Dwelling Registrations2026-08-12
- Registration Contacts2026-08-12
NYC OTI
- AddressPoint2026-07-07
- Building Footprints2026-10-19
NYC Rent Guidelines Board / NYS HCR