Printed 2026-10-20 from blueflo.tech/b/710-west-173-street-manhattan, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).
built 1922 · 5 stories · 48 apartments · BIN 1063436 · BBL 1021390312
- City records list the water service line as galvanized, requiring replacement
- 1 open immediately hazardous (class C) HPD violation about pests
- 8 open HPD violations about building conditions
- Boiler inspection filed Aug 2026 with no defects reported
- Outside FEMA's 1% annual-chance flood zone; no mapped stormwater flooding
- No heat or hot water complaints filed last winter
FORT 710 ASSOCCIATES LP, FORT 710 ASSOCIATES, L.P.
How often each problem is reported
2024 – 2026- General repairs2 reports20242025General repairs · Apr 2025 · 1 report (1 complaint)Apr 22, 20252026General repairs · Mar 2026 · 1 report (1 complaint)Mar 4, 2026
A filled month had a report to HPD; darker means more than one, and the past year is brightest. Tap one to read it. Complaints within a week count as one report. Records list complaints filed, not conditions found.
Apartments named in these records
Structure and facade
Issues on recordShow 6 more
- Facade ratingnot requiredNot required: facade inspections apply only to buildings taller than 6 stories
- Sidewalk shed and scaffoldingno recordNo sidewalk shed permits on record
- Landmark statusno recordNot in a historic district on record
Heat and hot water
1 complaint, 2025Latest accepted inspection Aug 2026, defects reported: no
What this counts
Accepted annual boiler inspection filings, any date
- Heat sourceno recordNo boiler registration or district steam on record
- Boiler work permitsno recordNo boiler work permits on record
- Heat and hot water complaintsfound0 heat or hot water complaints
Water and pipes
Issues on record · 2 complaints, 2025Galvanized Service Line Requiring Replacement (records)
Pests and cleanliness
Issues on record, most recently 2022Fire and safety
Older records on fileElectrical
1 complaint, 2025Flooding
No issues on recordOutside FEMA's 1% annual-chance flood zone: X
What this counts
Effective FIRM zones touching the building footprint
Extreme storm, 2080 sea levels: Not in mapped flooding; Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)
What this counts
Mapped ponding touching the building footprint
Below grade
Rent and tenancy
On the state listOn the state's list of buildings with at least one rent-stabilized apartment (2024 registrations); listed for this tax lot (1 addresses), not under this building's address
What this counts
The list doesn't say which apartments are stabilized, and being listed isn't proof of current status. For a specific apartment, request its rent history from HCR
Energy
ENERGY STAR score 73 (2024 report)
What this counts
Letter grades are issued by the city under Local Law 33 and posted near the building entrance; Blueflo shows the reported score only
General condition and all records
9 open: 8 about building conditions — walls, floors and stairs (4), doors and windows (1), fire safety (1), heat or hot water (1); 1 immediately hazardous (class C), 1 about paperwork or notices. 9 further violations from 2025–2026 were closed. 66 violations on record in all, 2011–2026 — the 18 most recent are listed here
Show 10 more
What this counts
Open HPD violations inspected in the last 10 years; class C = immediately hazardous. Paperwork = failure to file, notify or certify
2 general repairs, 1 doors or windows, 1 electrical, 1 floors or stairs, 1 heat or hot water, 1 leaks, 1 paint or plaster, 1 plumbing
What this counts
HPD complaints received in the last 2 years; the list below is every complaint on record for the last three years
19 permits since 1990
What this counts
DOB permits issued (DOB NOW and legacy BIS), one per job and work type; excludes sheds
- DOB violationsfound0 open
Nothing on record
- Gas pipingno recordNo open gas piping filing violations. Inspection results themselves are not published
- Elevatorsnot requiredNo elevators registered to this building
Sources
23 datasetsFEMA
- FEMA National Flood Hazard Layer2026-10-19
- OpenFEMA NFIP Redacted Claims (v3)2026-09-09
NYC DCP
- NYC GeoSearch (address directory)2026-10-19
- PLUTO (tax lot data)2026-08-24
NYC DEP
NYC DEP / Mayor's Office
- NYC Stormwater Flood Maps2024-07-03
NYC DOB
- DOB NOW Elevator Safety Compliance2026-10-18
- DOB NOW: Build – Approved Permits2026-10-17
- DOB NOW: Safety Boiler2026-10-17
- DOB NOW: Safety – Facades Compliance Filings2026-10-18
- DOB Permit Issuance (BIS)2026-10-19
- DOB Safety Violations2026-10-18
- DOB Violations2026-10-18
NYC DOB / Mayor's Office
NYC HPD
- Buildings Subject to HPD Jurisdiction2026-08-12
- Housing Maintenance Code Complaints and Problems2026-10-19
- Housing Maintenance Code Violations2026-10-19
- Multiple Dwelling Registrations2026-08-12
- Registration Contacts2026-08-12
NYC OTI
- AddressPoint2026-07-07
- Building Footprints2026-10-11
NYC Rent Guidelines Board / NYS HCR
Each date is when we last checked that dataset, not when the record itself was created.