Printed 2026-10-21 from blueflo.tech/b/668-46-street-brooklyn, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).
built 1928 · 3 stories · 6 apartments · BIN 3011987 · BBL 3007580036
- City records list the water service line as lead
- 10 open immediately hazardous (class C) HPD violations about pests and doors and windows and fire safety
- 2 open major (class 2) building code violations from 2023–2025
- 38 open HPD violations about building conditions
- Boiler inspection filed Mar 2026 with no defects reported
- Outside FEMA's 1% annual-chance flood zone; no mapped stormwater flooding
- No heat or hot water complaints filed last winter
668 AZN LLC, 668 AZN, LLC
How often each problem is reported
2024 – 2026- Mold2 reports2024Mold · Jan 2024 · 1 report (1 complaint)Jan 11, 20242025Mold · Mar 2025 · 1 report (1 complaint)Mar 13, 20252026
- Pests2 reports2024Pests · Jan 2024 · 1 report (1 complaint)Jan 11, 20242025Pests · Apr 2025 · 1 report (1 complaint)Apr 8, 20252026
- Doors or windows2 reports2024Doors or windows · Jan 2024 · 1 report (1 complaint)Jan 11, 20242025Doors or windows · Apr 2025 · 1 report (1 complaint)Apr 8, 20252026
- Safety2 reports2024Safety · Jan 2024 · 1 report (7 complaints)Jan 11, 2024Jan 11, 2024 (2nd)Jan 11, 2024 (3rd)Jan 11, 2024 (4th)Jan 11, 2024 (5th)Jan 11, 2024 (6th)Jan 11, 2024 (7th)2025Safety · Mar 2025 · 1 report (1 complaint)Mar 13, 20252026
A filled month had a report to HPD; darker means more than one, and the past year is brightest. Tap one to read it. Complaints within a week count as one report. Records list complaints filed, not conditions found.
Apartments named in these records
Heat and hot water
Issues on recordBoiler burning No. 2 oil (Peerless Ect 06 PEERLESS ECT 06), registration expired since Nov 1995
Latest accepted inspection Mar 2026, defects reported: no
What this counts
Accepted annual boiler inspection filings, any date
Latest boiler work permit 1996
What this counts
DOB boiler permits (BIS and DOB NOW); a permit dates work, not the boiler's age
- Heat and hot water complaintsfound0 heat or hot water complaints
Water and pipes
Issues on record, most recently 2025Lead (records)
Pests and cleanliness
Issues on record (2025) · 2 complaints, 2025Show 10 more
Fire and safety
Issues on record, most recently 2024Structure and facade
Issues on record, most recently 2025- Facade ratingnot requiredNot required: facade inspections apply only to buildings taller than 6 stories
- Sidewalk shed and scaffoldingno recordNo sidewalk shed permits on record
- Landmark statusno recordNot in a historic district on record
Flooding
No issues on recordOutside FEMA's 1% annual-chance flood zone: X
What this counts
Effective FIRM zones touching the building footprint
Extreme storm, 2080 sea levels: Not in mapped flooding; Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)
What this counts
Mapped ponding touching the building footprint
- Basementno recordUnknown
Gas
Open violation for not filing the periodic gas piping inspection (2025)
What this counts
Paperwork violation: the filing is missing, which is not a finding about the pipes
General condition and all records
42 open: 38 about building conditions — pests (8), mold (7), walls, floors and stairs (7), fire safety (5); 10 immediately hazardous (class C), 4 about paperwork or notices. Also 12 older records from 2010–2015 never closed. 12 further violations from 2024–2025 were closed. 165 violations on record in all, 2006–2026 — the 66 most recent are listed here
Show 29 more
What this counts
Open HPD violations inspected in the last 10 years; class C = immediately hazardous. Paperwork = failure to file, notify or certify
7 open: 3 about building conditions, 4 about filings or paperwork
What this counts
Open DOB, ECB and DOB NOW Safety violations, any date, one per violation. ECB class 1 = hazardous, class 2 = major
1 doors or windows, 1 mold, 1 paint or plaster, 1 pests, 1 safety
What this counts
HPD complaints received in the last 2 years; the list below is every complaint on record for the last three years
5 permits since 1990
What this counts
DOB permits issued (DOB NOW and legacy BIS), one per job and work type; excludes sheds
Show 8 more
Nothing on record
- Rent stabilizationno recordNot on the state's 2024 list. Owners who register late or not at all are missing, so ask HCR about a specific apartment
- Energynot requiredNot required: energy reporting applies to buildings over 25,000 sq ft
- Elevatorsnot requiredNo elevators registered to this building
Sources
23 datasetsFEMA
- FEMA National Flood Hazard Layer2026-10-20
- OpenFEMA NFIP Redacted Claims (v3)2026-09-09
NYC DCP
- NYC GeoSearch (address directory)2026-10-20
- PLUTO (tax lot data)2026-08-24
NYC DEP
NYC DEP / Mayor's Office
- NYC Stormwater Flood Maps2024-07-03
NYC DOB
- DOB NOW Elevator Safety Compliance2026-10-19
- DOB NOW: Build – Approved Permits2026-10-19
- DOB NOW: Safety Boiler2026-10-19
- DOB NOW: Safety – Facades Compliance Filings2026-10-19
- DOB Permit Issuance (BIS)2026-10-19
- DOB Safety Violations2026-10-19
- DOB Violations2026-10-19
NYC DOB / Mayor's Office
NYC HPD
- Buildings Subject to HPD Jurisdiction2026-08-12
- Housing Maintenance Code Complaints and Problems2026-10-20
- Housing Maintenance Code Violations2026-10-19
- Multiple Dwelling Registrations2026-08-12
- Registration Contacts2026-08-12
NYC OTI
- AddressPoint2026-07-07
- Building Footprints2026-10-19
NYC Rent Guidelines Board / NYS HCR
Each date is when we last checked that dataset, not when the record itself was created.