Building record from city data · MANHATTAN, NY

4499 Broadway

Printed 2026-10-20 from blueflo.tech/b/4499-broadway-manhattan, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).

built 1951 · 5 stories · 350 apartments on its tax lot · BIN 1085396 · BBL 1021800633

Checked in city records
Checked in city records: non-lead water line, outside FEMA flood zones, no open housing-condition violations
Source: FEMA National Flood Hazard Layer, Housing Maintenance Code Violations, Lead Service Line Location Coordinates · as of 2026-01-30
Also on record
Clean in the records
Registered with the city

FORT TRYON APARTMENTS CORP

Checked in city records
Checked in city records: non-lead water line, outside FEMA flood zones, no open housing-condition violations
Source: FEMA National Flood Hazard Layer, Housing Maintenance Code Violations, Lead Service Line Location Coordinates · as of 2026-01-30

Water and pipes

Older records on file
Water service lineWhole tax lot

Non-Lead (field inspection)

Lead Service Line Location Coordinates, as of 2026-01-30

Structure and facade

No issues on record
  • Facade ratingnot requiredNot required: facade inspections apply only to buildings taller than 6 stories
  • Sidewalk shed and scaffoldingfoundNo active shed permit; permits since Aug 2025, last expired Apr 2026
  • Landmark statusno recordNot in a historic district on record

Flooding

No issues on record
FEMA flood zone

Outside FEMA's 1% annual-chance flood zone: X

FEMA National Flood Hazard Layer, as of 2026-10-19
What this counts

Effective FIRM zones touching the building footprint

Stormwater flooding

Extreme storm, 2080 sea levels: Deep and contiguous flooding (1 ft+); Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)

NYC Stormwater Flood Maps, as of 2024-07-03
What this counts

Mapped ponding touching the building footprint

BasementWhole tax lot

Above grade

PLUTO (tax lot data), as of 2026-08-24

Rent and tenancy

On the state list
Rent stabilizationWhole tax lot

On the state's list of buildings with at least one rent-stabilized apartment (2024 registrations); listed for this tax lot (5 addresses), not under this building's address

Rent Stabilized Building Lists (2024 HCR registrations), as of 2025-11-30
What this counts

The list doesn't say which apartments are stabilized, and being listed isn't proof of current status. For a specific apartment, request its rent history from HCR

Energy

EnergyWhole tax lot

ENERGY STAR score 81 (2024 report), reported for all of Century - Fort Tyron Apartments Corp. (Parent Prop) (8 buildings)

Energy and Water Data Disclosure (Local Law 84), as of 2025-11-25
What this counts

Letter grades are issued by the city under Local Law 33 and posted near the building entrance; Blueflo shows the reported score only

General condition and all records

DOB violations

2 open: 2 older than 10 years

DOB Violations, as of 2026-10-18 · Read these violations in full at DOB →
What this counts

Open DOB, ECB and DOB NOW Safety violations, any date, one per violation. ECB class 1 = hazardous, class 2 = major

Permit history

1 permits since 1990

DOB NOW: Build – Approved Permits, as of 2026-10-17 · See every permit at DOB →
What this counts

DOB permits issued (DOB NOW and legacy BIS), one per job and work type; excludes sheds

  • HPD violationsfound0 open
  • Resident complaints to the cityfoundno complaints

Nothing on record

Heat and hot waterNo issues on record
  • Heat sourceno recordNo boiler registration or district steam on record
  • Boiler inspection filingsno recordNo boiler filings under this building's ID
  • Boiler work permitsno recordNo boiler work permits on record
  • Heat and hot water complaintsfound0 heat or hot water complaints
Gasno record
  • Gas pipingno recordNo open gas piping filing violations. Inspection results themselves are not published
ElevatorsNot applicable
  • Elevatorsnot requiredNo elevators registered to this building

Sources

21 datasets

Each date is when we last checked that dataset, not when the record itself was created.