Building record from city data · MANHATTAN, NY

408 W 46 St

Printed 2026-10-20 from blueflo.tech/b/408-west-46-street-manhattan, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).

built 1920 · 5 stories · 5 apartments · BIN 1026460 · BBL 1010550039

Worth knowing
2 open immediately hazardous (class C) HPD violations about fire safety and heat or hot water
Source: Housing Maintenance Code Violations · as of 2026-10-19
Worth knowing
Clean in the records
Registered with the city

Apex Management Group, 408 Owner LLC

Worth knowing
2 open immediately hazardous (class C) HPD violations about fire safety and heat or hot water
Source: Housing Maintenance Code Violations · as of 2026-10-19

How often each problem is reported

2024 – 2026

A filled month had a report to HPD; darker means more than one, and the past year is brightest. Tap one to read it. Complaints within a week count as one report. Records list complaints filed, not conditions found.

Apartments named in these records

1 of this building’s 5 apartments is named in a city record. The rest have no record naming them, which is the usual case.

These are city records about an apartment, not about anyone who lives or lived there. They may not be used to screen a tenant.

Heat and hot water

Issues on record (2025) · 5 complaints, 2024–2025
Heat source

Boiler burning natural gas (Weil Mclain Eg75Pi WEIL MCLAIN EG75PI), registration expired since Apr 1991

Clean Air Tracking System (boiler registrations), as of 2026-10-19 · See this building's boiler registrations on NYC Open Data →
Boiler inspection filings

Latest accepted inspection Mar 2021, defects reported: no

DOB NOW: Safety Boiler, as of 2026-10-17 · See the boiler filings at DOB →
What this counts

Accepted annual boiler inspection filings, any date

  • Boiler work permitsno recordNo boiler work permits on record
  • Heat and hot water complaintsfound0 heat or hot water complaints

Water and pipes

Issues on record, most recently 2022
Water service line

Unknown - Lead Status Unknown (records)

Lead Service Line Location Coordinates, as of 2026-01-30

Fire and safety

Issues on record, most recently 2022

Structure and facade

No issues on record
  • Facade ratingnot requiredNot required: facade inspections apply only to buildings taller than 6 stories
  • Sidewalk shed and scaffoldingno recordNo sidewalk shed permits on record
  • Landmark statusno recordNot in a historic district on record

Flooding

No issues on record
FEMA flood zone

Outside FEMA's 1% annual-chance flood zone: X

FEMA National Flood Hazard Layer, as of 2026-10-19
What this counts

Effective FIRM zones touching the building footprint

Stormwater flooding

Extreme storm, 2080 sea levels: Not in mapped flooding; Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)

NYC Stormwater Flood Maps, as of 2024-07-03
What this counts

Mapped ponding touching the building footprint

  • Basementno recordUnknown

General condition and all records

HPD violations

4 open: 4 about building conditions — fire safety (2), heat or hot water (1), plumbing (1); 2 immediately hazardous (class C). Also 1 older record from 1989 never closed. 21 violations on record in all, 1983–2025 — the 5 most recent are listed here

Housing Maintenance Code Violations, as of 2026-10-19 · Read these violations in full at HPD Online →
What this counts

Open HPD violations inspected in the last 10 years; class C = immediately hazardous. Paperwork = failure to file, notify or certify

Resident complaints to the city

5 heat or hot water

Housing Maintenance Code Complaints and Problems, as of 2026-10-19 · See the complaints at HPD Online →
What this counts

HPD complaints received in the last 2 years; the list below is every complaint on record for the last three years

Permit history

8 permits since 1990

DOB NOW: Build – Approved Permits, as of 2026-10-17 · See every permit at DOB →
What this counts

DOB permits issued (DOB NOW and legacy BIS), one per job and work type; excludes sheds

  • DOB violationsfound0 open

Nothing on record

Gasno record
  • Gas pipingno recordNo open gas piping filing violations. Inspection results themselves are not published
Energyno record
  • Energynot requiredNot required: energy reporting applies to buildings over 25,000 sq ft
ElevatorsNot applicable
  • Elevatorsnot requiredNo elevators registered to this building
Rent and tenancyNot applicable
  • Rent stabilizationnot requiredNot on the state's list. Rent stabilization generally applies to buildings with 6 or more apartments

Sources

23 datasets

Each date is when we last checked that dataset, not when the record itself was created.