Building record from city data · MANHATTAN, NY

350 Wadsworth Ave

Printed 2026-10-20 from blueflo.tech/b/350-wadsworth-avenue-manhattan, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).

built 2010 · 6 stories · 17 apartments · BIN 1089182 · BBL 1021700281

Checked in city records
Checked in city records: non-lead water line, outside FEMA flood zones and stormwater maps, elevator inspections current
Source: DOB NOW Elevator Safety Compliance, FEMA National Flood Hazard Layer, Lead Service Line Location Coordinates · as of 2026-01-30
Also on record
Clean in the records
Registered with the city

WADSAWORTH AVENUE/WADSWORTH TERRACE LLC, WADSWORTH AVENUE/WADSWORTH TERRACE, LLC

Checked in city records
Checked in city records: non-lead water line, outside FEMA flood zones and stormwater maps, elevator inspections current
Source: DOB NOW Elevator Safety Compliance, FEMA National Flood Hazard Layer, Lead Service Line Location Coordinates · as of 2026-01-30

Heat and hot water

No issues on record
What has happened here
Boiler inspection filings

Latest accepted inspection Jan 2025, defects reported: no

DOB NOW: Safety Boiler, as of 2026-10-17 · See the boiler filings at DOB →
What this counts

Accepted annual boiler inspection filings, any date

Boiler work permits

Latest boiler work permit 2011

DOB Permit Issuance (BIS), as of 2026-10-19
What this counts

DOB boiler permits (BIS and DOB NOW); a permit dates work, not the boiler's age

  • Heat sourceno recordNo boiler registration or district steam on record
  • Heat and hot water complaintsfound0 heat or hot water complaints

Water and pipes

No issues on record
Water service lineWhole tax lot

Non-Lead (records)

Lead Service Line Location Coordinates, as of 2026-01-30

Pests and cleanliness

Older records on file

Fire and safety

No issues on record
What has happened here

Structure and facade

No issues on record
  • Facade ratingnot requiredNot required: facade inspections apply only to buildings taller than 6 stories
  • Sidewalk shed and scaffoldingfoundNo active shed permit
  • Landmark statusno recordNot in a historic district on record

Flooding

No issues on record
FEMA flood zone

Outside FEMA's 1% annual-chance flood zone: X

FEMA National Flood Hazard Layer, as of 2026-10-19
What this counts

Effective FIRM zones touching the building footprint

Stormwater flooding

Extreme storm, 2080 sea levels: Not in mapped flooding; Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)

NYC Stormwater Flood Maps, as of 2024-07-03
What this counts

Mapped ponding touching the building footprint

BasementWhole tax lot

Below grade

PLUTO (tax lot data), as of 2026-08-24

Elevators

Issues on record, most recently 2023
Elevators

1 active elevator; latest periodic inspection Apr 2026

DOB NOW Elevator Safety Compliance, as of 2026-10-18 · See this building's elevators on NYC Open Data →
What this counts

Active elevator devices registered to this building ID

Rent and tenancy

On the state list
Rent stabilization

On the state's list of buildings with at least one rent-stabilized apartment (2024 registrations). Listed under the 421-a tax program, so stabilization can end when the exemption does

Rent Stabilized Building Lists (2024 HCR registrations), as of 2025-11-30
What this counts

The list doesn't say which apartments are stabilized, and being listed isn't proof of current status. For a specific apartment, request its rent history from HCR

General condition and all records

HPD violations

7 open: 7 about paperwork or notices. 1 further violation from 2023 was closed. 9 violations on record in all, 2015–2026 — the 8 most recent are listed here

Housing Maintenance Code Violations, as of 2026-10-19 · Read these violations in full at HPD Online →
What this counts

Open HPD violations inspected in the last 10 years; class C = immediately hazardous. Paperwork = failure to file, notify or certify

DOB violations

1 open: 1 about filings or paperwork

DOB Violations, as of 2026-10-18 · Read these violations in full at DOB →
What this counts

Open DOB, ECB and DOB NOW Safety violations, any date, one per violation. ECB class 1 = hazardous, class 2 = major

Permit history

7 permits since 1990

DOB NOW: Build – Approved Permits, as of 2026-10-17 · See every permit at DOB →
What this counts

DOB permits issued (DOB NOW and legacy BIS), one per job and work type; excludes sheds

  • Resident complaints to the cityfoundno complaints

Nothing on record

Gasno record
  • Gas pipingno recordNo open gas piping filing violations. Inspection results themselves are not published
Energyno record
  • Energynot requiredNot required: energy reporting applies to buildings over 25,000 sq ft

Sources

23 datasets