Building record from city data · BROOKLYN, NY

1640 Park Pl

Printed 2026-10-21 from blueflo.tech/b/1640-park-place-brooklyn, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).

built 1915 · 4 stories · 12 apartments · BIN 3036638 · BBL 3013750034

Worth knowing
9 open immediately hazardous (class C) HPD violations about heat or hot water and fire safety and pests
Source: Housing Maintenance Code Violations · as of 2026-10-19
Worth knowing
Clean in the records
Registered with the city

FAIRSTEAD MANAGEMENT, NYC PACT PRESERVATION PARTNERS LLC

Heat or hot water: 9 reports to the city since 2024
2024Heat or hot water · Jan 2024 · 1 report (2 complaints)Jan 16, 2024Jan 19, 2024Heat or hot water · Mar 2024 · 2 reports (4 complaints)Mar 8, 2024Mar 11, 2024Mar 20, 2024Mar 25, 2024Heat or hot water · Nov 2024 · 1 report (1 complaint)Nov 23, 2024Heat or hot water · Dec 2024 · 1 report (1 complaint)Dec 2, 2024
2025Heat or hot water · Feb 2025 · 1 report (1 complaint)Feb 17, 2025Heat or hot water · Dec 2025 · 2 reports (3 complaints)Dec 10, 2025Dec 26, 2025Jan 2, 2026
2026Heat or hot water · Feb 2026 · 1 report (1 complaint)Feb 8, 2026
Source: HPD Complaints and Problems · as of 2026-10-21

Apartments named in these records

5 of this building’s 12 apartments are named in a city record. The rest have no record naming them, which is the usual case.

These are city records about an apartment, not about anyone who lives or lived there. They may not be used to screen a tenant.

Fire and safety

Issues on record

Heat and hot water

Issues on record (2025) · 7 complaints, 2024–2026 · 4 in the past year
Heat source

Boiler burning natural gas (Utica MAGB-1800 (6 MODULES)), registration current since Aug 2024

Clean Air Tracking System (boiler registrations), as of 2026-10-20 · See this building's boiler registrations on NYC Open Data →
Boiler inspection filings

Latest accepted inspection Jun 2023, defects reported: no

DOB NOW: Safety Boiler, as of 2026-10-19 · See the boiler filings at DOB →
What this counts

Accepted annual boiler inspection filings, any date

Boiler work permits

Latest boiler work permit 2026 (2 on record)

DOB Permit Issuance (BIS), as of 2026-10-19
What this counts

DOB boiler permits (BIS and DOB NOW); a permit dates work, not the boiler's age

Heat and hot water complaints

4 heat or hot water complaints

Housing Maintenance Code Complaints and Problems, as of 2026-10-20 · See the complaints at HPD Online →
What this counts

HPD complaints, heat season 2025–26 (Oct 1–May 31)

Water and pipes

1 complaint, 2026
Water service line

Non-Lead (records)

Lead Service Line Location Coordinates, as of 2026-01-30

Pests and cleanliness

Issues on record, most recently 2025

Electrical

Older records on file

Structure and facade

Issues on record, most recently 2024
  • Facade ratingnot requiredNot required: facade inspections apply only to buildings taller than 6 stories
  • Sidewalk shed and scaffoldingfoundNo active shed permit; permits since Mar 2024, last expired Mar 2025
  • Landmark statusno recordNot in a historic district on record

Flooding

No issues on record
FEMA flood zone

Outside FEMA's 1% annual-chance flood zone: X

FEMA National Flood Hazard Layer, as of 2026-10-20
What this counts

Effective FIRM zones touching the building footprint

Stormwater flooding

Extreme storm, 2080 sea levels: Not in mapped flooding; Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)

NYC Stormwater Flood Maps, as of 2024-07-03
What this counts

Mapped ponding touching the building footprint

BasementWhole tax lot

Below grade

PLUTO (tax lot data), as of 2026-08-24

Energy

EnergyWhole tax lot

ENERGY STAR score 94 (2024 report), reported for all of CROWN HEIGHTS (8 buildings)

Energy and Water Data Disclosure (Local Law 84), as of 2025-11-25
What this counts

Letter grades are issued by the city under Local Law 33 and posted near the building entrance; Blueflo shows the reported score only

General condition and all records

DOB violations

3 open: 3 about filings or paperwork

DOB Violations, as of 2026-10-19 · Read these violations in full at DOB →
What this counts

Open DOB, ECB and DOB NOW Safety violations, any date, one per violation. ECB class 1 = hazardous, class 2 = major

Permit history

8 permits since 1990

DOB NOW: Build – Approved Permits, as of 2026-10-19 · See every permit at DOB →
What this counts

DOB permits issued (DOB NOW and legacy BIS), one per job and work type; excludes sheds

Nothing on record

Rent and tenancyNot on the state list
  • Rent stabilizationno recordNot on the state's 2024 list. Owners who register late or not at all are missing, so ask HCR about a specific apartment
Gasno record
  • Gas pipingno recordNo open gas piping filing violations. Inspection results themselves are not published
ElevatorsNot applicable
  • Elevatorsnot requiredNo elevators registered to this building

Sources

23 datasets

Each date is when we last checked that dataset, not when the record itself was created.