Building record from city data · BROOKLYN, NY

1355 Pacific St

Printed 2026-10-21 from blueflo.tech/b/1355-pacific-street-brooklyn, where it is kept current. These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked. Not a warranty. May not be used for tenant screening (terms of use).

built 1905 · 4 stories · 8 apartments · BIN 3029799 · BBL 3012010040

Worth knowing
8 open immediately hazardous (class C) HPD violations about doors and windows and pests and fire safety and mold and walls, floors and stairs
Source: Housing Maintenance Code Violations · as of 2026-10-19
Worth knowing
Also on record
Clean in the records
Registered with the city

GAYLEVAULT FINANCIAL SERVICE CO, GAYLEVAULT FINANCIAL SERVICES CO, HCP PROPERTIES, INC.

Mold: 2 reports to the city since 2024
2024
2025Mold · Aug 2025 · 1 report (1 complaint)Aug 8, 2025
2026Mold · Mar 2026 · 1 report (1 complaint)Mar 4, 2026
Source: HPD Complaints and Problems · as of 2026-10-21

Also reported

2024 – 2026

A filled month had a report to HPD; darker means more than one, and the past year is brightest. Tap one to read it. Complaints within a week count as one report. Records list complaints filed, not conditions found.

Apartments named in these records

3 of this building’s 8 apartments are named in a city record. The rest have no record naming them, which is the usual case.

These are city records about an apartment, not about anyone who lives or lived there. They may not be used to screen a tenant.

Heat and hot water

Issues on record
Heat source

Boiler burning natural gas (Weil Mclain EGH-95), registration expired since Apr 2016

Clean Air Tracking System (boiler registrations), as of 2026-10-20 · See this building's boiler registrations on NYC Open Data →
Boiler inspection filings

Latest accepted inspection Jun 2024, defects reported: no

DOB NOW: Safety Boiler, as of 2026-10-19 · See the boiler filings at DOB →
What this counts

Accepted annual boiler inspection filings, any date

  • Boiler work permitsno recordNo boiler work permits on record
  • Heat and hot water complaintsfound0 heat or hot water complaints

Water and pipes

Issues on record (2025) · 1 complaint, 2025
Water service line

Non-Lead (field inspection)

Lead Service Line Location Coordinates, as of 2026-01-30

Pests and cleanliness

Issues on record (2025) · 2 complaints, 2025–2026 · 1 in the past year

Fire and safety

Issues on record, most recently 2023

Electrical

Issues on record, most recently 2025

Structure and facade

Issues on record, most recently 2025

Flooding

No issues on record
FEMA flood zone

Outside FEMA's 1% annual-chance flood zone: X

FEMA National Flood Hazard Layer, as of 2026-10-20
What this counts

Effective FIRM zones touching the building footprint

Stormwater flooding

Extreme storm, 2080 sea levels: Not in mapped flooding; Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable)

NYC Stormwater Flood Maps, as of 2024-07-03
What this counts

Mapped ponding touching the building footprint

BasementWhole tax lot

Below grade

PLUTO (tax lot data), as of 2026-08-24

Gas

Gas piping

Open violation for not filing the periodic gas piping inspection (2025)

DOB Safety Violations, as of 2026-10-19
What this counts

Paperwork violation: the filing is missing, which is not a finding about the pipes

General condition and all records

HPD violations

27 open: 26 about building conditions — doors and windows (7), fire safety (4), walls, floors and stairs (4), smoke or CO detectors (3); 8 immediately hazardous (class C), 1 about paperwork or notices. Also 1 older record from 2008 never closed. 7 further violations from 2023–2024 were closed. 190 violations on record in all, 2008–2026 — the 35 most recent are listed here

Housing Maintenance Code Violations, as of 2026-10-19 · Read these violations in full at HPD Online →
What this counts

Open HPD violations inspected in the last 10 years; class C = immediately hazardous. Paperwork = failure to file, notify or certify

DOB violations

7 open: 3 about building conditions, 3 about filings or paperwork, 1 older than 10 years

DOB Violations, as of 2026-10-19 · Read these violations in full at DOB →
What this counts

Open DOB, ECB and DOB NOW Safety violations, any date, one per violation. ECB class 1 = hazardous, class 2 = major

Resident complaints to the city

2 doors or windows, 2 general repairs, 2 mold, 1 paint or plaster, 1 plumbing

Housing Maintenance Code Complaints and Problems, as of 2026-10-20 · See the complaints at HPD Online →
What this counts

HPD complaints received in the last 2 years; the list below is every complaint on record for the last three years

  • Permit historyno record0 permits since 1990

Nothing on record

Rent and tenancyNot on the state list
  • Rent stabilizationno recordNot on the state's 2024 list. Owners who register late or not at all are missing, so ask HCR about a specific apartment
Energyno record
  • Energynot requiredNot required: energy reporting applies to buildings over 25,000 sq ft
ElevatorsNot applicable
  • Elevatorsnot requiredNo elevators registered to this building

Sources

23 datasets

Each date is when we last checked that dataset, not when the record itself was created.