# 63 Morningside Ave, Manhattan

What New York City's public records say about this building. Page: https://blueflo.tech/b/63-morningside-avenue-manhattan

> These are city records, not an inspection by Blueflo. Every item shows its source and the date it was last checked.

## In one line

City records list the water service line as lead (Lead Service Line Location Coordinates, as of 2026-01-30)

## The building

- **Year built:** 1914 (PLUTO (tax lot data), as of 2026-08-24)
- **Stories:** 5 (Buildings Subject to HPD Jurisdiction, as of 2026-08-12)
- **Homes:** 10 (Buildings Subject to HPD Jurisdiction, as of 2026-08-12)

## Worth knowing

- City records list the water service line as lead
- 89 open immediately hazardous (class C) HPD violations about doors and windows and fire safety and walls, floors and stairs and heat or hot water and pests and leaks and mold and structure and facade
- 10 hazardous (class 1) building code violations from 2020–2025 are still open
- Basement on record, and the city's stormwater map shows flooding here in at least one storm scenario
- 10 open major (class 2) building code violations from 2017–2025
- 313 open HPD violations about building conditions

## Also on record

- City stormwater map shows deep and contiguous flooding at this building in the Extreme storm, 2080 sea levels scenario

## Clean in the records

- Outside FEMA's 1% annual-chance flood zone (FEMA National Flood Hazard Layer, as of 2026-10-19)
- No heat or hot water complaints filed last winter (Housing Maintenance Code Complaints and Problems, as of 2026-10-19)

## Building systems

- **Boiler inspection filings:** No boiler filings under this building's ID (DOB NOW: Safety Boiler, as of 2026-10-17)
- **Facade rating:** Not required: facade inspections apply only to buildings taller than 6 stories (DOB NOW: Safety – Facades Compliance Filings, as of 2026-10-18)
- **Water service line:** Lead (records) (Lead Service Line Location Coordinates, as of 2026-01-30)
- **FEMA flood zone:** Outside FEMA's 1% annual-chance flood zone: X (FEMA National Flood Hazard Layer, as of 2026-10-19)
- **Stormwater flooding:** Extreme storm, 2080 sea levels: Deep and contiguous flooding (1 ft+); Moderate storm, 2050 sea levels: Not in mapped flooding; Moderate storm, today's sea levels: Not in mapped flooding; Limited storm, today's sea levels: Not loaded (file format unreadable) (NYC Stormwater Flood Maps, as of 2024-07-03)
- **Basement:** Below grade (PLUTO (tax lot data), as of 2026-08-24)

## Violations and complaints

- **HPD violations:** 323 open: 313 about building conditions — walls, floors and stairs (98), doors and windows (82), leaks (27), fire safety (21); 89 immediately hazardous (class C), 10 about paperwork or notices. Also 202 older records from 2002–2016 never closed. 15 further violations from 2023–2025 were closed. 792 violations on record in all, 2002–2026 — the 540 most recent are listed here (Housing Maintenance Code Violations, as of 2026-10-19)
- **DOB violations:** 44 open: 28 about building conditions, 9 about filings or paperwork, 7 older than 10 years (DOB Violations, as of 2026-10-18)
- **Heat and hot water complaints:** 0 heat or hot water complaints (Housing Maintenance Code Complaints and Problems, as of 2026-10-19)
- **Resident complaints to the city:** 3 heat or hot water, 1 safety (Housing Maintenance Code Complaints and Problems, as of 2026-10-19)

## More systems

- **Rent stabilization:** Not on the state's 2024 list. Owners who register late or not at all are missing, so ask HCR about a specific apartment (Rent Stabilized Building Lists (2024 HCR registrations), as of 2025-11-30)
- **Heat source:** Boiler burning No. 2 oil (H. B. Smith 28-A6 H. B. SMITH 28-A6), registration expired since Dec 2011 (Clean Air Tracking System (boiler registrations), as of 2026-10-19)
- **Boiler work permits:** Latest boiler work permit 2014 (3 on record) (DOB Permit Issuance (BIS), as of 2026-10-19)
- **Elevators:** No elevators registered to this building (DOB NOW Elevator Safety Compliance, as of 2026-10-18)
- **Gas piping:** Open violation for not filing the periodic gas piping inspection (2026) (DOB Safety Violations, as of 2026-10-18)
- **Energy:** Not required: energy reporting applies to buildings over 25,000 sq ft (Energy and Water Data Disclosure (Local Law 84), as of 2025-11-25)

## Permits and work

- **Permit history:** 10 permits since 1990 (DOB NOW: Build – Approved Permits, as of 2026-10-17)
- **Sidewalk shed and scaffolding:** No active shed permit (DOB NOW: Build – Approved Permits, as of 2026-10-17)
- **Landmark status:** Not in a historic district on record (PLUTO (tax lot data), as of 2026-08-24)

## Registered with the city

- 63 MORNINGSIDE AVENUE HDFc (Agent, Registration Contacts)
- 63 MORNINGSIDE AVENUE HOUSING DEVELOPMENT FUND COR (CorporateOwner, Registration Contacts)
- 63 MORNINGSIDE AVENUE HOUSING DVLPMNT FU ND CORP (TaxLotOwner, PLUTO (tax lot data))

## More

- Every record behind this card: https://blueflo.tech/b/63-morningside-avenue-manhattan/records
- The same card as JSON: https://blueflo.tech/v1/buildings/63-morningside-avenue-manhattan
- Ask about any building from an assistant (MCP): https://blueflo.tech/mcp
- Report something wrong: https://blueflo.tech/dispute?slug=63-morningside-avenue-manhattan